Ozark IL AC and Heating Experts
Charlie’s Air Conditioning & Heating has delivered Ozark, IL excellent service for almost 40 years. We specialize in heating and air conditioning services as well as blown-in insulation.
Check out our glowing reviews and discover why your neighbors consider us to be their nearby heating and air company in Ozark, IL.
Recent Jobs and Reviews in Ozark, IL
Our Local Reviews by City
- Anna, IL (4)
- Benton, IL (23)
- Buncombe, IL (1)
- Cambria, IL (26)
- Carbondale, IL (219)
- Carterville, IL (762)
- Christopher, IL (11)
- Colp, IL (9)
- Crab Orchard Precinct, IL (2)
- Creal Springs, IL (11)
- De Soto, IL (50)
- Du Quoin, IL (20)
- Elkville, IL (7)
- Energy, IL (23)
- Goreville, IL (8)
- Grantsburg, IL (3)
- Grassy, IL (2)
- Harrisburg, IL (5)
- Herrin, IL (178)
- Hurst, IL (1)
- Johnston City, IL (36)
- Lick Creek Precinct, IL (1)
- Makanda, IL (40)
- Makanda Township, IL (1)
- Marion, IL (276)
- Mulkeytown, IL (6)
- Murphysboro, IL (33)
- Ozark, IL (5)
- Pittsburg, IL (11)
- Pomona, IL (4)
- Ross Township, PA (1)
- Royalton, IL (14)
- Sesser, IL (3)
- Tamaroa, IL (1)
- Thompsonville, IL (4)
- Valier, IL (1)
- Vienna, IL (10)
- West Frankfort, IL (50)
- Zeigler, IL (2)
Job Locations and Reviews
Daniel B.
Water in floor
Ozark, IL 62972
Steve R.
No AC, upon arrival both thermostats were satisfied at 74. Turned both on, noticed small amount of water around indoor unit in basement. Checked charge, found unit low on gas, watched water fall off of coil, this is common when low on refrigerant. Added 1.5 lbs of 410a, charge is perfect now. No more water fell off the coil, checked and confirmed drain was not clogged. Cleaned up water on floor. Tested both thermostats, working great. Unit has to have sprung a small leak, charge was good during maintenance in April. Would suggest a $185 leak search, or just wait until spring and we can look for it during maintenance
Ozark, IL 62972
Daniel B.
2024 PSCA AC Check Up Prepaid AC Maintenance
Ozark, IL 62972
Daniel B.
2024 Spring Check Up AC
Ozark, IL 62972
Daniel B.
2024 Spring Check Up AC
Ozark, IL 62972
Daniel B.
Heating Repair 2023 PSCA Heating Check Up Renewal Heating Maintenance Checked wire connections. Replaced filter. Thermostat is operating normally. Heat strips are operating normally. Defrost mode is operating normally. Puron levels are within range. A mouse got into the electrical compartment on the outdoor coil and damaged the capacitor and multiple wires. Repaired wires and replaced capacitor. Everything else was clean and checked out well. System is operating normally at this time.
Ozark, IL 62972
Review
Daniel B.
HVAC Repair Complaint, no heat on downstairs system. Cause of the issue was a bad breaker inside the breaker panel. Replaced breaker and tested system operation. Heat strip #3 had a bad connection which was causing the wire to occasionally arc. Repaired connection. System is operating normally at this time.
Ozark, IL 62972
Daniel B.
AC Maintenance PCSA 2023 AC Check Up Prepaid Replaced filter. Checked wire connections. Flushed drain line. Cleaned outdoor coil. Puron levels were within range. Everything was clean and checked out well. System is operating normally at this time.
Ozark, IL 62972
Daniel B.
There was a slight hump in the drain under the house. Lowered it to help prevent any sort of double trapping. System appears to be draining properly. Upstairs system needed 2 lbs of R-410A. Customer would like to have a check up on both systems when possible.
Ozark, IL 62972
Daniel B.
Upstairs system had a cracked drain trap which caused the secondary drain pan to fill up with water. Replaced and heavily insulated drain trap, cleaned out drain pan, and flushed drain line. Wet switch also would not reset and needed replaced. Replaced wet switch and system appears to be operating normally at this time.
Ozark, IL 62972
Review
Daniel B.
PCSA 2022 Heating Check Up Renewal Blower motor/wheel appears to be slightly off balance but not having any issues. System could be a little low on R-410A but not enough to add any at this time. Everything else was clean and checked out well. Will monitor during future check ups. System is operating normally at this time.
Ozark, IL 62972
Review
Daniel B.
Nothing coming on. Cause of the issue was tripped breaker and low voltage fuse. Reset breaker and replaced fuse. Showed customer which breakers need to be off to clean electrified filter. System is operating normally at this time.
Ozark, IL 62972
Review
Daniel B.
PCSAS 2022 a/c check up prepaid Contactor was looking very worn out again. Replaced it with a heavier grade one under warranty. Everything else was clean and checked out well. System is operating normally at this time.
Ozark, IL 62972
Shawn C.
Found bad contactor replaced. Did maint on other downstairs unit. Both cooling at this time all checks good, filter downstairs needs replaced.
Ozark, IL 62972
Daniel B.
Heating Furnace Repair - Cause of the issue was tripped limit. When the power went out while the furnace was running, rising heat from the heat exchanger caused the limit to trip. Reset limit, replaced filters, and checked system operation. Everything seemed to be operating normally at this time. Strongly recommend customer installs CO detector when possible.
Ozark, IL 62972
Gerson C.
Replaced contactor points very burnt. New filter customer stock. Damper for upstairs blowing by or sticking, very tight access, do they want to pursue this house for sale?
Ozark, IL 62972
Gerson C.
Mini split in resale shop not cooing well. Topped off charge tightened fittings. Got non repeatable hits inside . Cleaned filters should be done regularly.
Ozark, IL 62972
Daniel B.
PCSA 2021 PREPAID AC MAINTENANCE Everything was clean and checked out well. System is operating normally at this time.
Ozark, IL 62972
Steve R.
Noise, turned on unit it made the noise it’s from the unit rubbing the wall. Put foam behind it, seemed to fix it. If it happens again we need to send a couple guys to take the unit off the wall and foam tape the backside
Ozark, IL 62972
Steve R.
Unit makes a knocking noise on initial start up during cold mornings in heat mode. Inspected unit cycled system, everything checked out. Spoke to Carl at crescent he said to adjust the charge, if that doesn’t work it’s probably something expanding or a reversing valve screwing up. Adjusted charge, if it happens again we need to be here on a cold morning to see it start up
Ozark, IL 62972
Daniel B.
1x Heating Only Check Up ckd system elec. heaters ok fefrigerant ok unit defrosts.
Ozark, IL 62972
Review
Daniel B.
Contactor on outdoor coil was looking very worn. Replaced contactor and system is operating normally. Everything else was clean and checked out well.
Ozark, IL 62972